Generador de 250 KW Deutz
- Delivery time: 30 days after the deposit is received.
- Warranty: 1 year or 5000 running hours.
- Payment terms: 30% as deposit, balance is paid before shipment.
- Packing: wood case.
SPECIFICATIONS
1: Each ignition is controlled accurately by ECU (see enclosed picture)
2: Gas inlet is with Italian imported pressure-reducing valve (see enclosed picture)
3: Gas and air mixing is controlled by mixer imported from USA (IMPCO), electric governor is of Chinese top brand (see enclosed picture).
4: Ignition cable and sparkling plug are Chinese top brand
5: Engine protection functions (warning or stop engine when water temp is high, high oil pressure, high oil temp, high speed)
6: Show alternator and engine parameters by LCD screen.
7: automatically start genset or stop genset.
8: can realize the “ remote control” of the genset.
9: voltage output automatically adjusted by AVR module.
The gas generator will require the following:
1: Gas inlet pressure: 80KPA – 300 kpa
2: Methane content in the gas: 85% – 95%
3: Temperature: -30℃~40℃
4: Altitude: ≤ 4000m
5: Relative air humidity: ≤90%
6: The circulating water should be soft water, cooling water should be alkaline clean water, must not have rust compound, such as acid, chloride etc. Main request of water:
I: Hardness: 0.7~5.3me/L
II: Chloride: <150mg/L
III: PH: 7~8.5
Note:
After purification, the gas should have no liquid oil or water, the dust content of gas should be <10mg/m3, particle size of dust should be <50μm,sulfide <20 mg/m3. The purification of gas is very important to the life time of genset, the continuous running time should be less than 300 hours each time, then stop and maintain the genset, maintenance time should be about 3 hours each time.
GAS GENERATOR SET PARAMETERS
Genset model
250GFT, SILENT TYPE
Engine model
Original Deutz - BF8M1015
Engine Type
Water cooled, 4 stroke, V shaped cylinder
Genset rated output power
250kw
Rated voltage
380V
Phase
3 phase
HZ
50Hz
Rpm
1500 r/min
Power factor
0.8
Rated current
450A
Steady-state voltage regulation
≤±2%
The transient voltage regulation rate
≤±10%
Voltage settling time
≤1S
Voltage fluctuation rate
≤±0.5%
Frequency steady state regulation
≤0.5%
Transient frequency regulation
≤±10%
Frequency recovery time
≤3S
Frequency fluctuation rate
≤0.5%
Voltage adjust range
95-105%
Heat consumption
≤7mj/kw.h
Oil consumption
≤1.0g/kw.h
Gas pressure
80-300kpa
Cylinders NO
8 cylinders V shaped
Bore
132mm
Stroke
145mm
Compression ratio
17:1
Start method
24V electric start
Big repair period
≥80000 hours
Noise level
≤90 Db
Intake method
Turbo charged and inter-cooled
Ignition method
By sparkling plug
Pressure adjustment method
Adjust pressure automatically
Speed governing type
Electric governor
Lubricating method
Forced and splashed type
Cooling type
Closed cooling with radiator (100% copper)
Exhaust temp
≤650℃
Displacement
16 L
Size
3050*1550*1950mm
Weight
2850 kg
gAS eNGINE PARAMETERS
Engine power
320KW
Total displacement(L)
16
Engine model
BF8M1015
Exhaust temp
≦650
Rated voltage
24V (electric start)
Shock range(mm/s)
≦0.4
Rated speed
1500
Intake method
Turbo charged inter cooled
Power factor
0.8 (delay)
Ignition method
By sparkling plug
Heat consumption (kj/kw.h)
≦7000
Air consumption(m3/h)
10000
Gas pressure (kpa)
≧80
Start method
24v electric start
Oil consumption (g/kw.h)
≦1.0
Speed adjust method
By electric governor
Oil volume (L)
80
Cooling method
Closed with radiator
Water volume (L)
High temp 160
Low temp 140
Lubricating method
Radiator
Forced and splashed type Hight temp radiator
Overhaul time (h)
40000
Protection class
IP21
Noise level (Db)
≦90
Insulation class
H
Cylinders NO
6
Generating rate
98%
Emission
EURO 3
gENERATOR SET PROTECTION FUNCTIONS
Alarm and stop for hight/low voltage
alarm for hight water temp
Alarm and stop for hight/low HZ
alarm for high oil temp
Alarm and stop for short circuit
alarm and stop for hight / low oil pressure
Alarm and stop for over speed
Alarm and stop for high current
GENSET CONTROL
Main switch adopts automatic smart air breaker, which has the protection function of higher current, low voltage etc.
When there is break, the main switch will cut off automatically and send light& sound signal.
It is with controller, all kinds of instruments, adjusting buttons, engine protection indicating light, emergency stop button etc, they are used to control and monitoring the genset work situation.
The genset speed is controlled by electric governor, and it can also be adjusted slightly by speed ajust button.
The output voltage is adjusted automatically( By AVR)
There is flow-charging device for battery in the cabinet.
tHE DASHBOARD CAN MONITOR THE FOLLOWING PARAMETERS:
3 phase AC output current and voltage
Low oil pressure alarm
Engine speed
HZ
high oil temp alarm
Inlet and outlet water temp
Battery voltage
over speed alarm
Inlet Oil pressure
Speed adjust button
Voltage adjust button
Outlet Oil temp
Switch on/off
Oil temp
Alarm for high temp
Running time
TOTALLY OFFER LIST
NAME
QUANTITY
NAME
QUANTITY
Gas Engine
(with ignition cable, sparkling plug)
1 piece
Alternator
1 piece
Common base frame
1 piece
Silent shell
1 set
ATS system (without automatic transfer)
1 piece
Control cable
1 set
Pressure-adjusted valve
1 piece
Air-gas mixer
(with governor)
1 piece
Tube fire blocker
1 piece
radiator
1 piece
Wave tube for exhaust
1 piece
tools
1 set
Battery, start cabinet
1 set
Operation book
1 set
ECU for ignition
1 piece
For silent type gas generator set:
1: noise level will reach to about 75dB at 6 m.
2: silent shell is 4mm thickness
3: with50mm thickness sound-enclosure cotton
4: with platic-spraying workmanship, high anti-rust performance.