Generador de 60 KW Deutz

Código BF8M1015 Categoría Marca

  • Delivery time: 120 days after the deposit is received.
  • Warranty: 1 year or 5000 running hours.
  • Payment terms: 30% as deposit, balance is paid before shipment.
  • Packing: wood case.

  • Delivery time: 120 days after the deposit is received.
  • Warranty: 1 year or 5000 running hours.
  • Payment terms: 30% as deposit, balance is paid before shipment.
  • Packing: wood case.
SKU: BF8M1015 Categoría: Etiqueta:

Descripción

SPECIFICATIONS

CORE FUNCTIONS OF GAS GENERATOR SET 1: Each ignition is controlled accurately by ECU (see enclosed picture) 2: Gas inlet is with Italian imported pressure-reducing valve (see enclosed picture) 3: Gas and air mixing is controlled by mixer imported from USA (IMPCO), electric governor is of Chinese top brand (see enclosed picture). 4: Ignition cable and sparkling plug are Chinese top brand 5: Engine protection functions (warning or stop engine when water temp is high, high oil pressure, high oil temp, high speed) 6: Show alternator and engine parameters by LCD screen. 7: Can realize “remote control” of the genset (optional) 8: Voltage output automatically adjusted by AVR module. 9: Rated output power is 60kw PARAMETERS The gas generator will require the following: 1: Gas inlet pressure: 1.5 bar – 5 bar 2: Methane content in the gas: 85% – 95% 3: Temperature: -30℃~40℃ 4: Altitude: ≤ 4000m 5: Relative air humidity: ≤90% 6: The circulating water should be soft water, cooling water should be alkaline clean water, must not have rust compound, such as acid, chloride etc. I: Hardness: 0.7~5.3me/L II: Chloride: <150mg/L III: PH: 7~8.5
Note: After purification, the gas should have no liquid oil or water, the dust content of gas should be <10mg/m3, particle size of dust should be <50μm,sulfide <20 mg/m3. The purification of gas is very important to the life time of genset, the continuous running time should be less than 300 hours each time, then stop and maintain the genset, maintenance time should be about 3 hours each time.

GAS GENERATOR SET PARAMETERS

Genset model 60GFT, OPEN TYPE Engine model Deutz 6105 Engine Type Water cooled, 4 stroke, cylinder inline Genset rated output power 60kw Rated voltage 380V Phase 3 phase HZ 50Hz Rpm 1500 r/min Power factor 0.8 Rated current 108A Steady-state voltage regulation ≤±2% The transient voltage regulation rate ≤±10% Voltage settling time ≤1S Voltage fluctuation rate ≤±0.5% Frequency steady state regulation ≤0.5% Frequency recovery time ≤3S Frequency steady state regulation ≤0.5% Voltage adjust range 95-105% Heat consumption ≤7mj/kw.h Oil consumption ≤1.0g/kw.h Gas pressure 1.5-5 bar Cylinders NO 6 cylinders in line Bore 105mm Stroke 130mm Compression ratio 19:1 Start method 24V electric start Big repair period ≥20000 hours Noise level ≤90 Db Intake method Naturally aspirated Ignition method By sparkling plug Pressure adjustment method Adjust pressure automatically Speed governng type Electric governor Lubricating method Forced and splashed type Cooling type Closed cooling with radiator (100% copper) Exhaust temp ≤650℃ Displacement 9.3L Size 2350*980*1450mm Weight 1250 kg

gAS eNGINE PARAMETERS

Engine power 68KW Total displacement(L) 4.33 Engine model Deutz 6105 Exhaust temp ≦650 Rated voltage 24V (electric start) Shock range(mm/s) ≦0.4 Rated speed 1500 Intake method Naturally aspirated Power factor 0.8 (delay) Ignition method By spark plug Heat consumption (kj/kw.h) ≦3000 Air consumption(m3/h) 15000 Gas pressure (kpa) ≧1.5 Start method 24v electric start Oil consumption (g/kw.h) ≦1.0 Speed adjust method By electric governor Oil volume (L) 45 Cooling method Closed with radiator Water volume (L) High temp 80 Low temp 60 Lubricating method Radiator Forced and splashed type Hight temp radiator Overhaul time (h) 20000 Protection class IP21 Noise level (Db) ≦90 Insulation class H Cylinders NO 6 Generating rate 98% Emission EURO 3

gENERATOR SET PROTECTION FUNCTIONS

Alarm and stop for hight/low voltage alarm for hight water temp Alarm and stop for hight/low HZ alarm for high oil temp Alarm and stop for short circuit alarm and stop for hight / low oil pressure Alarm and stop for over speed Alarm and stop for high current

GENSET CONTROL

The control system is fixed to one end of genset (on the top of alternator). Main switch adopts automatic smart air breaker, which has the protection function of higher current, low voltage etc. It is with 4 protection module which can send alarms when there is high water temperature, high oil temperature, high oil pressure and high speed. The output voltage is adjusted automatically (by AVR) There is flow-charging device for battery in the cabinet.

tHE DASHBOARD CAN MONITOR THE FOLLOWING PARAMETERS:

3 phase AC output current and voltage Low oil pressure alarm Engine speed HZ high oil temp alarm Water temp Battery voltage over speed alarm Oil pressure Alarm for high water temp Oil temp Alarm and stop for high current

TOTALLY OFFER LIST

NAME

QUANTITY

NAME

QUANTITY

Gas Engine (with ignition cable, spark plug) 1 piece Alternator 1 piece Common base frame 1 piece​ Silent shell ATS system (without switch) Control cable 1 set Pressure-adjusted valve 1 piece​ Air-gas mixer radiator 1 piece Tube fire blocker 1 piece​ radiator 1 piece Wave tube for exhaust 1 piece​ tools 1 set Battery, start cabinet 1 set Operation book 1 set ECU for ignition 1 piece​