Generador de 1 KWA CATERPILLAR - POCO USO
CONTINUOUS 1030 ekW 1287 kVA.
50 Hz · 1500 rpm · 400 Volts
SPECIFICATIONS
G3516 LE SCAC 4-stroke-cycle, spark-ignited engine.
- Number of Cylinders: V16.
- Bore — mm (in): 170 (6.7).
- Stroke — mm (in): 190 (7.5).
- Displacement — L (cu in): 69 (4210).
- Compression Ratio: 11:01.
- Aspiration: Turbocharged Separate Circuite Aftercooled.
- Cooling Type: JW, combined SCAC & O/C.
- Fuel System: Low Pressure.
- Governor Type (516GEX1): Woodward 2301A.
- Frame size: 697.
- Excitation: Permanente Magnet.
- Pitch: 0.7333.
- Number of poles: 4.
- Number or bearings: 1.
- Number of leads: 6.
- Insulation: Class H.
- IP rating: Drip proof IP22.
- Alignment: Pilot Shaft.
- Overspeed capability — % of rated: 125%.
- Waveform deviation line to line, no load: less than 3.0%.
- Voltage regulator: CDVR.
- Voltage level adjustment: +/- 5.0%.
- Voltage regulation, steady state: +/- 0.5%.
- Voltage regulation with 3% speed change: +/- 0.5%.
- Telephone Influence Factor (TIF): less than 50.
- Instrument panel includes:
- Oil pressure.
- Water temperature.
- Oil pressure differential.
- Inlet manifold temperature.
- Service meter.
- Exhaust pyrometer and thermocouples.
- Intake manifold pressure gauge.
TECHNICAL DATA
g3516 gAS gENERATOR SET
DM 0761
Emission level (NOx)
Aftercooler SCAC
mg/Nm3
Deg C
500
54
Package Performance (1)
Power Rating @ 0.8 pf (w/water pumps and w/o fan)
Power Rating @ 0.8 pf (w/water pumps and w/o fan)
Power Rating @ 1.0 pf (w/water pumps and w/o fan)
Electric Efficiency @ 1.0 pf (ISO 3046/1) (2)
Mechanical Power (w/water pumps and w/o fan)
ekW Continuous
kVA Continuous
ekW Continuous
%
bkW
1030
1287
1039
32
1070
Fuel Consumption (3)
100% load w/o fan
75% load w/o fan
50% load w/o fan
Nm3/hr
Nm3/hr
Nm3/hr
526
433
315
Altitude Capability
At 25 Deg C (77 Deg F) ambient, above sea level
M
500
Cooling System
Ambient air temperature
Jacket water temperature ( Maximum outlet )
Deg C
Deg C
25
110
Exhaust System
Combustion air inlet flow rate
Exhaust stack gas temperature
Exhaust gas flow rate
Nm3/min
Deg C
Nm3/min
67.9
479
78.8
Heat Rejection
Heat rejection to jacket water
Heat rejection to AC and OC
Heat rejection to exhaust (LHV to 25 Deg C)
Heat rejection to exhaust (LHV to 120 Deg C)
Heat rejection to atmosphere from engine
Heat rejection to atmosphere from generator
kW
kW
kW
kW
kW
kW
817
316
929
701
112
40.7
Generator
Frame
Temperature rise
Motor starting capability @30% voltage dip (4)
Deg C
skVA
697
105
2259
Emissions (5)
NOx @ 5% O2 (dry)
CO @ 5% O2 (dry)
THC @ 5% O2 (dry)
NMHC @ 5% O2 (dry)
Exhaust O2 (dry)
mg/Nm3
mg/Nm3
mg/Nm3
mg/Nm3
%
500
1119
1375
207
6.5